IDLffDicomExCfg::Init

Syntax | Return Value | Arguments | Keywords | Example | Version History

The IDLffDicomExCfg::Init function method initializes the IDLffDicomExCfg object. The IDLffDicomExCfg object allows you to set and retrieve the values of IDL DICOM Network Service configuration parameters. For an introduction to IDL's DICOM Network Service feature, see Using IDL DICOM Network Services.

By default, the IDLffDicomExCfg::Init method creates an association between the returned object and the user's local DICOM Network Services configuration file. Use the SYSTEM keyword to create an object associated with the system-wide configuration file. See Local Versus System Configuration for additional information on the difference between the system and local configurations.

Note
Init methods are special lifecycle methods, and as such cannot be called outside the context of object creation. This means that in most cases, you cannot call the Init method directly. There is one exception to this rule: if you write your own subclass of this class, you can call the Init method from within the Init method of the subclass.

Syntax

Obj = OBJ_NEW('IDLffDicomExCfg' [, /SYSTEM])

or

Result = Obj->[IDLffDicomExCfg::]Init( [, /SYSTEM] )
(In a lifecycle method only.)

Return Value

When this method is called indirectly, as part of the call to the OBJ_NEW function, the return value is an object reference to the newly-created object.

When called directly within a subclass Init method, the return value is 1 if initialization was successful, or zero otherwise.

Note
This feature requires an additional-cost license key to access the functionality. If a valid feature license can not be found, an error is returned. For more information, contact your ITT Visual Information Solutions sales representative or technical support.

Arguments

None

Keywords

SYSTEM

Set this keyword to create an IDLffDicomExCfg object associated with the DICOM Network Services system configuration file. By default, the created object is associated with the user's local configuration file.

Example

The following example code shows how to write and read a configuration file.

Note
Executing these commands will change the directory used by your local Storage SCP service. If you have already configured this value, be sure to change it back to your original value before retrieving files.

; Create a new object associated with the system configuration file. 
ocfg = OBJ_NEW('IDLffDicomExCfg', /SYSTEM) 
 
; Stop the Storage SCP Service before making changes. 
status = ocfg->StorageScpService('stop') 
PRINT, 'Stopping Storage SCP. Status: ', status 
WAIT, 5 
 
; Add a Storage SCP Application Entity. 
ocfg->SetApplicationEntity, 'my_stor_scp_aen', $ 
   'my_stor_scp', 'my_machine_name', 2510,  $ 
   'Storage_SCP_Service_List', 'Storage_SCP' 
 
; Set the Storage SCP service to the entry created above. 
ocfg->SetValue, 'StorScpServiceAE', 'my_stor_scp_aen' 
 
; Set the local IDL Storage SCP directory to the 'MyStorScpDir' 
; directory under the user's HOME directory. 
myStorScpDir = GETENV('HOME') + PATH_SEP() + 'MyStorScpDir' 
ocfg->SetValue, 'StorScpDir', myStorScpDir 
 
; Save the changes and write the configuration file back to disk. 
ocfg->Commit 
 
; Restart the Storage SCP Service. 
status = ocfg->StorageScpService('start') 
PRINT, 'Starting Storage SCP. Status: ', status 
WAIT, 5 
status = ocfg->StorageScpService('status') 
PRINT, 'Storage SCP Status: ', status 
 
; Retrieve the definition for the Application Entity 
; created above. 
defAE = ocfg->GetApplicationEntity('my_stor_scp_aen') 
HELP, defAE, /STRUCTURE 
 
; Retrieve the name of the Application Entity for the  
; Storage SCP service. 
serviceAE = ocfg->GetValue('StorScpServiceAE') 
PRINT, serviceAE 
 
; Retrieve the directory to be used by the Storage SCP service. 
scpDir = ocfg->GetValue('StorScpDir') 
PRINT, scpDir 
 
; Destroy the configuration object. 
OBJ_DESTROY, ocfg 

Version History

6.3

Introduced